REFERENCE: PINBALL AIRBORNE V1.4 SOFTWARE UPDATE
DEAR DISTRIBUTOR,
ENCLOSED YOU WILL FIND VERSION 1.4 CPU SOFTWARE UPDATE FOR AIRBORNE. PLEASE REPLACE U1H AND UIL EPROMS ON THE CPU PCB WITH THE NEW VERSION EPROMS INCLUDED.
THE FOLLOWING IS A LIST OF CHANGES IMPLEMENTED WITH VERSION 1.4 SOFTWARE:
* THE UP/DOWN RAMP OPTO WILL NOW REMAIN ACTIVE AFTER GAME OVER. THIS WILL
ALLOW THE GAME TO CLEAR ANY BALLS THAT MAY BE UNDER THE RAMP WITHOUT
HAVING TO WAIT FOR BALL SEARCH.
* ADDED LANGUAGE TRANSLATIONS FOR GERMAN, DUTCH, FRENCH, AND SPANISH.
* THE UP/DOWN RAMP 1 SECOND ACTIVATION DELAY HAS BEEN REMOVED. WHEN A BALL IS
READ BY THE RAMP OPTO IT WILL IMMEDIATELY RAISE.
* THE LEFT RAMP JACKPOT LAMP IS NO LONGER BLINKED WHEN MULTIPLE RAMP SHOTS
ARE BEING MADE.
* THE INITIAL HIGH SCORE TO DATE TABLE AND REPLAY LEVEL SCORES ARE
AUTOMATICALLY INCREASED WHEN THE GAME IS CHANGED FROM A 3 BALL GAME TO A
5 BALL GAME.
* OUTLANE GATE DIVERTER COIL CONTROL ADJUSTED FOR COOLER OPERATION.
* REPLAY SCORE FACTORY DEFAULT SETTING HAS BEEN LOWERED FROM 100 MILLION TO
75 MILLION.
* PERFORMING A FACTORY RESET NOW SETS VOLUME LEVEL TO 8.
* REPLAY BUMP FACTORY DEFAULT SETTING LOWERED FROM 10 MILLION TO 1 MILLION.
* REPLAY MINIMUM FACTORY DEFAULT SETTING LOWERED FROM 60 MILLION TO 1 MILLION.
NOTE: THE CHANGE TO THE DEFAULT SETTINGS FOR REPLAY BUMP AND REPLAY MINIMUM WILL ALLOW FOR AN EVEN MORE ACCURATE CALCULATION OF THE SUGGESTED REPLAY LEVEL.
IF YOU HAVE ANY QUESTIONS REGARDING THIS OR ANY OTHER ISSUE, PLEASE FEEL FREE TO CONTACT THE FIELD SERVICE DEPARTMENT.